Technical Resources

Installation manuals, engineering documentation, cut sheets, and material data for the mounting system Raptor Racking is built on.

Sourcing & Attribution Notice

Raptor Racking mounting hardware is manufactured under a white-label engineering and manufacturing program. The engineering letters, PE stamps, and technical documents below were issued to that program's manufacturer of record and are reproduced here unaltered, in their original form. They apply to the underlying mounting system Raptor Racking sells — a Raptor-specific reissue of this documentation is in progress and will replace these as it's completed.

01Installation Manuals

Leading Edge T-Clamp Installation Manual
UL 2703 bonding system — module-to-module clamp installation
PDF · 12 pages
Rev. Sep 2017
Download

02Product Cut Sheets

Composition Roof Cut Sheet
Mount specification for composition shingle roofs
PDF · 2 pages
Rev. Jul 2013
Download
Standing Seam Cut Sheet
Mount specification for standing seam metal roofs
PDF · 1 page
Rev. Jan 2013
Download
Micro-Inverter Trunk Cable / Rail Data
Cable management reference for micro-inverter installs
PDF · 2 pages
Rev. Jul 2013
Download

03Engineering & PE Stamps

State-specific engineering letters and PE stamps for the underlying mounting system, evaluated to ASCE 7 / IBC wind-load provisions for the design wind speed and roof deck noted. Confirm current applicability for your jurisdiction before permitting.

AZ · 120 MPH
Arizona PE Stamp
Engineering letter, design wind speed 120 mph
Download
CA · 130 MPH
California PE Stamp
Engineering letter, design wind speed 130 mph
Download
CO · 120 MPH
Colorado PE Stamp
Engineering letter, design wind speed 120 mph
Download
FL · 130 MPH
Florida PE Stamp
Engineering letter, design wind speed 130 mph
Download
HI · 200 MPH
Hawaii PE Stamp
Engineering letter, design wind speed 200 mph
Download
LA · 130 MPH
Louisiana PE Stamp
Engineering letter, design wind speed 130 mph
Download
MD · 110 MPH
Maryland PE Stamp
Engineering letter, design wind speed 110 mph
Download
MN · 116 MPH
Minnesota PE Stamp
Engineering letter, design wind speed 116 mph
Download
MO · 129 MPH
Missouri PE Stamp
Engineering letter, design wind speed 129 mph
Download
NJ · 200 MPH
New Jersey PE Stamp
Engineering letter, design wind speed 200 mph
Download
NM · 120 MPH
New Mexico PE Stamp
Engineering letter, design wind speed 120 mph
Download
NY · 160 MPH
New York PE Stamp
Engineering letter, design wind speed 160 mph
Download
OR · 135 MPH
Oregon PE Stamp
Engineering letter, design wind speed 135 mph
Download
PA · 120 MPH
Pennsylvania PE Stamp
Engineering letter, design wind speed 120 mph
Download
SC · 180 MPH
South Carolina PE Stamp
Engineering letter, design wind speed 180 mph
Download
TX · 120 MPH
Texas PE Stamp
Engineering letter, design wind speed 120 mph
Download
CODE EVALUATION
Engineering Code Evaluation Report
Third-party code compliance evaluation of the mounting system design assumptions (ASCE 7 / IBC / IRC)
Download
TX · ANCHOR ENGINEERING
Anchor Engineering Letter — Texas
Reviewed and sealed letter covering fastener requirements by roof pitch and wind speed for 7/16" OSB decking
Download

04Material Data

Butyl Material Safety Data
Sealant material safety data sheet
PDF · 3 pages
Rev. Sep 2007
Download
Kwikseal II Woodbinder Technical Data
Fastener/sealant screw technical data sheet
PDF · 1 page
Rev. Apr 2013
Download
MB10A Sealant Tape Technical Data
Butyl sealant tape technical data sheet
PDF · 2 pages
Rev. Oct 2007
Download

05Warranty Documents

Raptor-branded warranty documentation is pending confirmation as part of the white-label program.

See Warranty for current status.